Commercial Door Repair Charlotte NC Charlotte door repair(984) 266-2968
Charlotte, NC · Panic bars

Panic Bar & Exit Device Repair in Charlotte

An exit device has two jobs: let people out instantly, and keep the door latched and secure the rest of the time. When a panic bar sticks, will not release, will not relatch or rattles loose, we repair it for Charlotte businesses, schools, churches and multifamily buildings.

Call about panic bars
(984) 266-2968

Most urgent sign: The door will not open from the inside

Symptoms

What it is doing, and what that usually means

Panic Bar & Exit Device Repair: symptoms, likely causes and urgency
What you seeWhat it usually meansHow urgent
Push bar will not release the doorLatch, rod or internal mechanism failureCall now
Door will not latch when it closesStrike or rod out of line, or a sagging doorCall today
Pair of doors will not close togetherVertical rod or coordinator problemCall today
Push pad is loose or sticksWorn mechanism or loose mountingCall today
Outside trim or key will not workTrim, cylinder or connection failureCall today
Bar must be pushed very hardBinding latch or door pressure on the strikeThis week

Call now Someone could be hurt, the building is not secure, or people cannot get out. Call today The door is failing at its basic job and it will get worse with every cycle.

What we check

The inspection

The part named on the call is rarely the only one involved. These are checked on every panic bar & exit device repair visit in Charlotte:

  • Push pad and mechanismTravel, return and smooth release.
  • Latch boltsProjection, wear and engagement in the strike.
  • Vertical rodsTop and bottom latches, rod length and bends.
  • StrikesAlignment and wear on the frame or floor.
  • Outside trimLever, pull or cylinder and its connection to the device.
  • DoggingWhether the device may be dogged (not on fire exit hardware).
Technician in a hard hat adjusting the latch hardware on the edge of a commercial door with a screwdriver
Latch, strike and lock body are checked together: the lock is only as good as the door it closes into.

Life safety first

Exit devices are life-safety hardware. If a door will not open from the inside, treat it as urgent, keep other exits clear and tell the people in the building. Chaining, padlocking or blocking an exit while you wait for a repair is never the answer.

Fire exit hardware is different

On a fire-rated door, the exit device has to be listed as fire exit hardware and must latch every time the door closes. That usually means no mechanical dogging, no removing top or bottom rods, and replacement parts suited to the opening. Mention any fire label on the door or frame when you call.

Straight answers

Repair or replace?

Usually repairable

  • Latch, rod and strike adjustment
  • Worn push pads, mechanisms and outside trim
  • Re-mounting loose devices

Replacement makes sense

  • Devices with broken internal parts that are no longer available
  • Rim devices on a door that needs a different function
  • Hardware that does not match the fire rating of the opening

Have this ready when you call

  • Single door or a pair
  • Brand and model on the device, if visible
  • Whether the door will open from the inside right now
  • Any fire label on the door edge or frame
Call about panic bars
(984) 266-2968
In Charlotte

Panic bars in Charlotte buildings

Exit devices see heavy use in Uptown office lobbies, University City schools and campuses, South End multifamily buildings and the churches throughout Charlotte. Stairwell and corridor doors in mid-rise buildings are common panic-bar calls.

FAQ

Panic Bar & Exit Device Repair: questions

Can I lock a panic bar door with a chain at night?

No. Exits must stay usable while the building is occupied. Ask about the right hardware for after-hours security instead.

Why will my pair of doors not latch?

Usually a vertical rod is out of adjustment, a door is sagging, or a coordinator is not letting the doors close in order.

Can a panic bar be repaired, or must it be replaced?

Many problems are adjustments or worn parts. Replacement makes sense when internal parts are unavailable or the function is wrong for the door.

What is dogging?

Holding the latch retracted so the door can be pushed open freely. It is not allowed on fire exit hardware.

Do you repair exit devices on glass storefront doors?

Yes. Narrow-stile exit devices on aluminum doors are common in Charlotte storefronts.

Panic Bar & Exit Device Repair in Charlotte

Sticking, not latching or not releasing. Call and describe the door.

Call about panic bars
(984) 266-2968
Call (984) 266-2968